Instadose body dosimeter

SCK CEN - Dosimetrie (2019)

A weekly overview for every employee

Instadose: for faster dose monitoring without administrative burden

Employees, students, trainees, independent physicians... every occupationally exposed employee must wear a dosimeter at chest height. With the accredited Instadose dosimeters, SCK CEN ensures an accurate measurement of the effective dose for the whole body.

Benefits of the Instadose dosimeter of SCK CEN:

  • Measuring range from 80 µSv up to maximum 1 Sv
  • One dosimeter can be used by multiple persons: practical for visitors
  • Weekly results are immediately available online thanks to the wireless connection with the base station
  • Monthly results can be validated and checked within 6 working days after the end of the month
  • User-friendly online portal for management and reporting
  • Support from a team of experts in the interpretation of measurement results, based on SCK CEN’s 50 years of experience

Technical specifications

The Instadose dosimeter is available in two versions: Instadose+ and Instadose2. Instadose+ only measures Hp(10) and is therefore somewhat cheaper than Instadose2, which monitors both Hp(10) and Hp(0.07).

Instadose+

Minimally detectable dose

80 µSv

Type of radiation

photons

Measuring range

80 µSv up to 1 Sv

Measured units

Hp(10)

Energy range

24 keV – 1.25 MeV

Instadose2

Minimally detectable dose

80 µSv

Type of radiation

photons

Measuring range

Hp(10): from 80 µSv  up to 1 Sv
Hp(0.07): from 150 µSv up to 1 Sv

Measured units

Hp(10) and Hp(0.07)

Energy range

24 keV – 1.25 MeV

The Instadose dosimeters are based on the Direct Ion Storage (DIS) principle, with incident ionising radiation generating electrical charges in a miniature ionisation chamber. These charges are subsequently stored in a semiconductor memory cell. The amount of charge in the memory cell is a measure of the cumulative radiation dose. When reading the dosimeter, the amount of charge is recorded in a non-destructive way through a voltage measurement. As such, the charge accumulates and is not lost. The dose over a given period of time is then calculated by establishing the difference between both correct readings.

Download the Instadose brochure for more information.

Download

Looking for more information or a personalised solution?

Complete the form below and we will contact you as soon as possible.

Please add any application forms here or provide us with more information regarding a question. Would you like to share multiple files? Then we advise you to combine everything in a zip-file and upload it.
One file only.
16 MB limit.
Allowed types: gif, jpg, jpeg, png, bmp, eps, tif, pict, psd, txt, rtf, html, odf, pdf, doc, docx, ppt, pptx, xls, xlsx, xml, avi, mov, mp3, ogg, wav, bz2, dmg, gz, jar, rar, sit, svg, tar, zip.

Share this page